Mixed-Mode S-Parameter Measurements for Determination of Cable Coupling
Mixed-Mode S-Parameter Measurements for Determination of Cable Coupling
| dc.contributor.author | Lansink Rotgerink, J.H.G.J. | |
| dc.contributor.author | Moonen, N. | |
| dc.contributor.author | Leferink, F. | |
| dc.date.accessioned | 2025-06-27T12:50:59Z | |
| dc.date.available | 2025-06-27T12:50:59Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Single-ended S-parameters are used to quantify electromagnetic coupling, or crosstalk, between cables. The use of this measurement technique is demonstrated on a case where crosstalk occurs between two wire pairs above ground. S-parameter measurements involve no elements that introduce frequency restrictions, such as baluns or current clamps. Moreover, by measuring or simulating all combinations of S-parameters and converting these to mixed-mode S-parameters, not only differential-mode (DM), but also common-mode (CM) and mode-conversion S-parameters are obtained. When only the coupling between a specific combination of cables is desired, it is sufficient to measure only a small subset of all S-parameters. Finally, the relation between crosstalk as defined in the standards and the obtained S-parameters is discussed | |
| dc.identifier.citation | J. L. Rotgerink, N. Moonen and F. Leferink, "Mixed-Mode S-Parameter Measurements for Determination of Cable Coupling," 2019 ESA Workshop on Aerospace EMC (Aerospace EMC), Budapest, Hungary, 2019, pp. 1-6, doi: 10.23919/AeroEMC.2019.8788948. | |
| dc.identifier.uri | https://hdl.handle.net/10921/1761 | |
| dc.language.iso | en | |
| dc.publisher | IEEE | |
| dc.title | Mixed-Mode S-Parameter Measurements for Determination of Cable Coupling | |
| dc.type | Other |
Files
Original bundle
1 - 1 of 1
- Name:
- MixedMode_Sparameters.pdf
- Size:
- 2.37 MB
- Format:
- Adobe Portable Document Format
- Description: